THREE SELECTABLE D.C. RANGES
0to10V,0(4)to20mA,0to50mA
MINIMUM AND MAXIMUM DISPLAY CAPTURE
LCD, REFLECTIVE OR RED/GREEN LED BACKLIGHTING
0.48" (12.2 mm) HIGH DIGITS
OPTIONAL SETPOINT OUTPUT MODULES
OPTIONAL SERIAL COMMUNICATIONS MODULES (RS232 or RS485)
OPERATES FROM 9 TO 28 VDC POWER SOURCE
FRONT PANEL OR CRIMSON PROGRAMMABLE
DISPLAY COLOR CHANGE CAPABILITY AT SETPOINT OUTPUT
NEMA 4X/IP65 SEALED FRONT BEZEL
1950 SERIES - COMPACT SMART SYSTEM 5-DIGIT PROCESS METER
GENERAL DESCRIPTION
INPUT
SAFETY SUMMARY
All safety related regulations, local codes and instructions that appear in this
literature or on equipment must be observed to ensure personal safety and to
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.
Do not use this meter to directly command motors, valves, or other actuators
not equipped with safeguards. To do so can be potentially harmful to persons or
equipment in the event of a fault to the meter.
CAUTION: Risk of Danger.
Read complete instructions prior to
installation and operation of the unit.
CAUTION: Risk of electric shock.
DIMENSIONS In Inches (mm)
Note: Recommended minimum clearance (behind the panel) for mounting clip installation is 2.15" (54.6) H x 3.00" (76.2) W.
The 1950 Series provides the user the ultimate in flexibility, from its
complete user programming to the optional setpoint control and communication-
capability. The 1950 accepts a DC voltage or current input signal and provides a
display in the desired unit of measure. The meter also features minimum and
maximum display capture, display offset, units indicator, and programmable-
user input. The display can be toggled either manually or automatically between
the selected displays.
The 1950 display has 0.48" (12.2 mm) high digits. The LCD is available in two
versions, reflective or red/green backlight. The backlight version is user
selectable for the desired color and also has variable display intensity.
The capability of the 1 9 5 0 can be easily expanded with the addition of
option modules. The setpoint output cards are field installable with
programmable setpoints. Serial communications capability for RS232 or RS485
can be added with a serial option module.
The 1 950 can be powered from an optional N OSH OK Micro-
Line/SensorPower Supply (PS3), which attaches directly to the back of a 1950.
The PS3 is powered from 85 to 250 VAC and provides up to 400 mA to drive the
unit and sensors.
The 1950 is a DC Process meter. It features voltage and current input ranges,
that are selected by the user via a programming jumper and software input range
selection. The ranges consist of the following: 0 to 10 V, 0(4) to 20mA, or 0 to
50 mA. Users should select the appropriate voltage range that covers their
maximum input.
Vue de la page 0
1 2 3 4 5 6 ... 15 16

Résumé du contenu

Page 1 - DIMENSIONS In Inches (mm)

1THREE SELECTABLE D.C. RANGES0to10V,0(4)to20mA,0to50mAMINIMUM AND MAXIMUM DISPLAY CAPTURELCD, REFLECTIVE OR RED/GREEN LED BACKLIGHTING0.48" (12.2

Page 2 - GENERAL METER SPECIFICATIONS

Enter the reset action of the output. See figure for details.Auto = Automatic action; This action allows the output to automatically reset offat the t

Page 3 - 1.0 INSTALLING THE METER

116.5 MODULE 5 - SERIAL SETUP PARAMETERS (5-SEr)The Serial Setup Parameters are only active when the optional RS232 or RS485 serial communications mo

Page 4 - 3.0 INSTALLING PLUG-IN CARDS

1950 PROGRAMMING QUICK OVERVIEWPress and hold SEL buttonto enter Programming Mode.12

Page 5

NOTES13

Page 8 - MODE DESCRIPTIONDISPLAY

CORPORATE HEADQUARTERS1010 West Bagley Road • Berea, Ohio 44017440-243-0888 • FAX 440-243-3472E-MAIL: [email protected]: www.noshok.comUM195008-1

Page 9

1. DISPLAY: 5 digit LCD 0.48" (12.2 mm) high digits1950X-1 : Reflective LCD with full viewing angle1950X-2 : Transmissive LCD with selectable red

Page 10

3ADDING OPTION CARDSThe 1950 meters can be fitted with optional output cards and/or serialcommunications cards. The details for the plug-in cards can

Page 11 - PARAMETER MENU

WIRING OVERVIEWElectrical connections are made via screw-clamp terminals located on theback of the meter. All conductors should conform to the meter’s

Page 13

65.0 REVIEWING THE FRONT BUTTONS AND DISPLAYPROGRAMMING MODE ENTRY (SEL BUTTON)It is recommended all programming changes be made off line, or beforein

Page 14

76.1 MODULE 1 - SIGNAL INPUT PARAMETERS (1-INP)PARAMETER MENUª«10urAN6E1950 INPUT RANGESelect the input range that corresponds to the external signal

Page 15

Entering Code 50 will display the version (x.x) of themeter. The display then returns to CodE 00. Press the SELbutton to exit the module. Entering Cod

Page 16 - CORPORATE HEADQUARTERS

9The Security Code determines the programming mode and the accessibilityof programming parameters. This code can be used along with the ProgramMode Lo

Commentaires sur ces manuels

Pas de commentaire